HomeProductsHCG PregnancyHcg Pregnancy Cassetteone step urine HCG pregnancy test For Women OEM ISO13485 US FDA approve
  • one step urine HCG pregnancy test For Women OEM ISO13485 US FDA approve
  • one step urine HCG pregnancy test For Women OEM ISO13485 US FDA approve
  • one step urine HCG pregnancy test For Women OEM ISO13485 US FDA approve
  • one step urine HCG pregnancy test For Women OEM ISO13485 US FDA approve

one step urine HCG pregnancy test For Women OEM ISO13485 US FDA approve

  • $0.08
    20000-99999
    Piece/Pieces
  • $0.08
    100000-999999
    Piece/Pieces
  • $0.07
    ≥1000000
    Piece/Pieces
  • Product Description
Overview
Product Attributes

Model No.Cassette

Brandkangzhou

Place Of OriginChina

Type Of DisinfectionFar Infrared

Functional UseDiagnostic Instruments

InventoryYes

Shelf Life3 Years

MaterialPvc

Product Quality CertificationCe, Msds, Tuv, Ul

Medical Device ClassificationClass Ii

Safety StandardEn 149 -2001+A1-2009

UseCheck if a woman is pregnant

CertificateFDA,CE,ISO13485

Size2.5mm/3.0mm/4.0mm

Supply Ability & Additional Information

Packaging1pc/foil bah , 40pcs/zipper bag or 50pcs/middle box ,

Productivity4000000pcs/week

TransportationOcean,Land,Air,Express

Place of OriginChina

Supply Ability4000000pcs/week

CertificateISO13485

HS Code3822190090

Portweihai ,qingdao ,shanghai

Payment TypeL/C,T/T,D/P

IncotermFOB,DDU,CFR,CIF,EXW,Express Delivery

Packaging & Delivery
Selling Units:
Piece/Pieces
Package Type:
1pc/foil bah , 40pcs/zipper bag or 50pcs/middle box ,
Picture Example:

Intended Use

The Pregnancy One Step Rapid Test Cassette is a rapid, one step test for the qualitative detection of human chorionic gonadotropin (HCG) in urine, as an aid for the early detection of pregnancy. The test is intended for in vitro diagnostic self-testing.

Principle

The Pregnancy One Step Rapid Test Cassette adopts the principles of double antibody sandwich method and immunochromatography to test the human chorionic gonadotropin (hCG) in the urine. The membrane is pre-coated with anti-hCG antibodies in the test region (T) and anti-mouse antibodies in the control region (C). During testing, the urine sample reacts with the colored conjugate (mouse anti-hCG antibody colloidal gold conjugate) which has been pre-coated on the test strip. The mixture then migrates upward on the membrane to react with anti-hCG antibodies in the test region and generate a red line. Presence of the red line indicates a positive result, while its absence indicates a negative result. Regardless of the presence of hCG, as the mixture continues to migrate across the control region, a red line at the region will always appear. The presence of this red line serves as verification for sufficient sample volume and proper flow and as a control for the reagents.


Storage and Stability

1. Store as packaged in the sealed pouched at room temperature (2-30℃). The kit is stable within the expiration date printed on the labeling.

2. Once open the pouch, the test strip should be used within 1 hours. Prolonged exposure to ambient humidity will cause product deterioration.




Specimen

The first morning urine is preferred since it generally contains the highest concentration of hCG. However, urine at any time of day may be used. Urine

specimens may be stored at 2-8 ℃ for up to 72 hours prior to assay.






Interpretation of Results

Positive: Two distinct red lines will appear, one in the test region (T) and one in the control region (C).Positive test results are possible but not definitive for the diagnosis of pregnancy. It is strongly recommended that an additional urine specimen be obtained after 48-72 hours and tested again, or consulting your physician.

 

Negative: Only a single red line appears in the control region (C). No apparent red or pink line appears in the test region (T). Negative test results mean that you may not be pregnant.However, you should re-test with the first morning specimen obtained 48-72 hours later.

 

Invalid: Control band fails to appear which means improper testing procedures or deterioration of reagents probably occurred. In any event, repeat the test. If the problem persists, discontinue using the lot immediately and contact your local distributor.

 

Notes: The shade of red color in the test region (T) will vary depending on the concentration of hCG present. However, neither the quantitative value nor the rate of increase in hCG can be determined by this qualitative test.


00




Product Categories : HCG Pregnancy > Hcg Pregnancy Cassette

Email to this supplier
  • *Subject:
  • *To:
    Mr. Ni Xinyong
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
HomeProductsHCG PregnancyHcg Pregnancy Cassetteone step urine HCG pregnancy test For Women OEM ISO13485 US FDA approve
Send Inquiry
*
*

Related Products List

Home

Product

Phone

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send